Signal Booster Specications
Dual-Band
800/1900 MHz Specications
Model Number / Part Number 2B1401 / 811207, 811209
Connectors FME-Male
Impedance (input/output) 50 ohms
Dimensions
5 x 5.4 x 1.4 inch or 14 x 10.8 x 3.5 cm
Weight 1.32 lbs or 0.6 kg
Frequency 824-894 MHz / 1850-1990 MHz / GSM 1575 MHz
1
Passband Gain (nominal)
800 MHz and 1900 MHz 20 dB
1575 MHz 8 dB
2
20 dB Bandwidth (nominal)
800 MHz (uplink/downlink) 50 MHz / 49 MHz
1900 MHz (uplink/downlink) 121 MHz / 94 MHz
3
Power output for single cell phone (uplink) 800 MHz 1900 MHz
CDMA 33 dBm
29.6 dBm
GSM 32.6 dBm 27.3 dBm
EDGE 33.1 dBm 27.8 dBm
WCDMA 33.5 dBm 29.7 dBm
3
Power output for single received channel
(downlink)
800 MHz 1575 MHz 1900 MHz
CDMA
9.7 dBm 13.6 dBm
GSM 8.7 dBm 9.6 dBm
EDGE 9.1 dBm 12.3 dBm
AMPS 10.3 dBm 11.9 dBm
GPS 18 dBm
4
Power output for multiple received
channels (downlink). The maximum
power is reduced by the number of
channels:
Number of
channels
Maximum Power
800 MHz 1900 MHz
2
10.1 dBm 10.9 dBm
3 6.5 dBm 7.4 dBm
4 4.0 dBm 4.9 dBm
5 2.1 dBm 2.9 dBm
6 0.5 dBm 1.4 dBm
Noise Figure (typical) 3 dB nominal
Isolation > 90 dB
Power Requirements
Signal Booster Usage
12 V, .5 A - 1.5 A (subject to uplink power)
Notes:
1. Nominal gain is the maximum gain at any frequency in the passband.
2. Nominal bandwidth is the difference between two frequencies that are adjacent to the passband where the amplication is
20 dB lower than the passband amplication. One of the frequencies is lower than the passband and the other is higher.
3. The Manufacturer’s rated output power of this equipment is for single carrier operation. For situations when multiple
carrier signals are present, the rating would have to be reduced by 3.5 dB, especially where the output signal is re-
radiated and can cause interference to adjacent band users. This power reduction is to be by means of input power or
gain reduction and not by an attenuator at the output of the device.
4. The maximum power for 2 or more simultaneous signals will be reduced by 6 dB every time the number of signals is doubled.
Part #110930 AIG - FRENCH 001 070111
3301 East Deseret Drive, St. George, UT 84790
For additional Technical Support visit www.WilsonElectronics.com
or email at: tech@wpsantennas.com
Phone: (507)282-8484
www.twitter.com/WilsonCellular www.facebook.com/WilsonCellular
Vista de pagina 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 23 24

Comentarios a estos manuales

Sin comentarios